Interior insulation for excellent airtightness

Installing Interior insulation is a quick way of increasing living comfort. Specifically developed for this application, the OPTIMA System combines a simple-to-fit lightweight metal framework with high levels of thermal insulation. The dry installation can be carried out easily:

Step 1: After the OPTIMA metal studs have been fixed to the floor, wall and ceiling, fit vertical studs.

Step 2: Overlap VARIO KM Duplex UV by 10-15 cm. Create an airtight bond using VARIO KB1 or VARIO MultiTape. Bond junctions with wall and floor using VARIO DS or VARIO ProTape to make the structure airtight.

Step 3: Make cable penetrations airtight with VARIO MultiTape SL. VARIO Stos or Mangete Passelec are ideal for sealing off various other installations.